Why T₂* and S₀ Vary Across the Brain#
The previous chapter described multi-echo data with the monoexponential decay model,
and focused on how \(T_{2}^{*}\) and \(S_{0}\) fluctuate over time. This chapter looks at their average values instead. A map of mean \(T_{2}^{*}\) or \(S_{0}\) is far from uniform: \(T_{2}^{*}\) is short above the sinuses and in the basal ganglia and long in the ventricles, and \(S_{0}\) is brighter near the edges of the brain than in the middle. Below, we describe the physical and physiological mechanisms behind these patterns, starting with the different kinds of transverse relaxation.
\(R_{2}^{*}\), \(R_{2}\), and \(R_{2}'\)#
It is often easier to think about relaxation rates than relaxation times. A relaxation rate is the inverse of the corresponding time (\(R_{2}^{*} = 1 / T_{2}^{*}\)), and is usually given in units of \(s^{-1}\) (or Hz). Rates are convenient because independent sources of relaxation add up: if two mechanisms each dephase the signal, the total decay rate is the sum of their individual rates.
After excitation, the transverse magnetization in a voxel decays for two broad reasons.
Irreversible dephasing (\(R_{2} = 1 / T_{2}\)). Water molecules move and interact with their neighbors, so each spin experiences rapidly and randomly fluctuating magnetic fields. The phase errors that this produces are random, and they cannot be undone. This is “true” transverse relaxation, and it is what a spin-echo sequence measures.
Reversible dephasing (\(R_{2}' = 1 / T_{2}'\)). If the magnetic field varies within a voxel but stays constant over time, spins in different parts of the voxel precess at slightly different frequencies. They gradually fall out of phase with one another, and the summed signal shrinks. Because each spin keeps the same frequency, a 180° refocusing pulse can reverse this dephasing, which is why a spin echo is insensitive to it.
A gradient-echo sequence, which is what almost all BOLD fMRI uses, has no refocusing pulse, so it is sensitive to both:
Because \(R_{2}'\) can never be negative, \(T_{2}^{*}\) is always shorter than \(T_{2}\).
The field variations that cause \(R_{2}'\) are usually split by their spatial scale [Yablonskiy and Haacke, 1994, Ulrich and Yablonskiy, 2016]:
Macroscopic variations happen on a scale similar to or larger than a voxel. The typical example is the field gradient near air-tissue boundaries, such as the sinuses and ear canals. These depend on the head, the shim, and the imaging parameters, not just on the tissue in the voxel.
Mesoscopic variations happen on a scale much smaller than a voxel, but much larger than the distance a water molecule diffuses during the echo time. They are caused by small objects with a magnetic susceptibility that differs from that of the surrounding tissue, such as venules and veins containing deoxyhemoglobin, iron-rich cells, and myelinated axons. These are properties of the tissue.
The line between reversible and irreversible dephasing is not perfectly sharp. Water that diffuses through the field around a very small object, such as a capillary, experiences a field that changes over time from the spin’s perspective. That part of the dephasing cannot be refocused, so it contributes to \(R_{2}\) rather than \(R_{2}'\). This is why spin-echo BOLD fMRI still has some sensitivity to deoxyhemoglobin, mostly from the smallest vessels.
The figure below shows decay curves for a voxel with the same \(R_{2}\), with and without additional \(R_{2}'\). The values are illustrative.
Fig. 17 Signal decay with only irreversible dephasing (\(R_{2}\), as measured with a spin echo) and with additional reversible dephasing (\(R_{2}'\), as measured with a gradient echo). The relaxation times are illustrative.#
Everything that follows is a story about which of these terms changes from one region to another. Multi-echo gradient-echo fMRI only measures their sum, \(R_{2}^{*}\). Separating \(R_{2}\) from \(R_{2}'\) requires additional measurements, such as spin echoes or a combined gradient-echo/spin-echo sequence [Ulrich and Yablonskiy, 2016, He and Yablonskiy, 2007].
Mean \(T_{2}^{*}\) and \(S_{0}\) in real data#
To see what these maps look like, we fit the monoexponential model to the mean of each echo
from the five-echo run used throughout this book,
which was acquired at 3T.
We use tedana’s log-linear fit and adaptive mask,
which limits the fit in each voxel to the echoes with good signal.
This section uses a cortical and subcortical parcellation from fMRIPrep, in addition to the files listed in Download Data:
datalad get sub-24053/ses-1/anat/sub-24053_ses-1_desc-aparcaseg_dseg.nii.gz
Fig. 18 Mean \(S_{0}\) (top) and \(T_{2}^{*}\) (bottom) estimated from a five-echo resting-state run at 3T. The \(T_{2}^{*}\) color scale is capped at 100 ms, so the ventricles saturate.#
Fig. 19 Median \(T_{2}^{*}\) and \(S_{0}\) in selected regions from the FreeSurfer parcellation, restricted to voxels with at least two good echoes.#
Several patterns stand out, and each points to a different mechanism:
The median \(T_{2}^{*}\) across cortex is 54 ms, but it is only 32 ms in lateral orbitofrontal cortex and 32 ms in inferior temporal cortex. These regions sit above the sinuses and next to the ear canals (Macroscopic field inhomogeneity and air-tissue boundaries).
In the basal ganglia, \(T_{2}^{*}\) is shortest in the globus pallidus (30 ms), followed by the putamen (37 ms) and the caudate (43 ms). This is the same order as their iron content (Iron).
\(T_{2}^{*}\) is shorter in white matter (48 ms) than in cortex (Myelin and fiber orientation).
The ventricles have a very long \(T_{2}^{*}\) (155 ms), but a lower \(S_{0}\) than brain tissue, even though cerebrospinal fluid (CSF) contains more water (T_{1} saturation).
\(S_{0}\) also varies smoothly across the head, in patterns that do not follow tissue boundaries (Coil sensitivity).
The rest of this chapter describes these mechanisms.
Sources of \(T_{2}^{*}\) variability#
Macroscopic field inhomogeneity and air-tissue boundaries#
The magnetic susceptibility of air differs from that of tissue, so the main magnetic field (\(B_{0}\)) is distorted wherever the two meet. In the head, this happens mostly above the sinuses and around the ear canals, which affects orbitofrontal cortex, ventromedial prefrontal cortex, and the inferior and anterior temporal lobes, including the amygdala [Ojemann et al., 1997]. The field near these boundaries changes across a single voxel, so spins at one edge of the voxel precess at a different frequency from spins at the other edge. This is \(R_{2}'\) dephasing on a macroscopic scale, and it is responsible for the dark “dropout” regions in long-TE images.
Macroscopic dephasing is not a property of the tissue. It depends on the voxel size (bigger voxels span a larger range of field values), the slice orientation, the head’s position in the scanner, and how well the field was shimmed [Reichenbach et al., 1997]. The same orbitofrontal voxel will have a different apparent \(T_{2}^{*}\) in different acquisitions. Field gradients in the phase-encoding direction can also shift the echo in k-space, which changes the effective echo time of the voxel [Deichmann et al., 2002].
These gradients also change the shape of the decay. For a field that changes linearly across a slice of thickness \(\Delta z\), the signal is multiplied by a sinc function [Fernández-Seara and Wehrli, 2000]:
where \(\Delta f\) is the difference in frequency between the top and the bottom of the slice and \(\mathrm{sinc}(x) = \sin(\pi x) / (\pi x)\). This decay is not monoexponential. It decays slowly at short echo times and quickly at longer echo times, and the signal can even reappear briefly after the first zero of the sinc. Fitting a monoexponential model to these data produces an apparent \(R_{2}^{*}\) that is too high, by up to 100% in brain at 1.5 and 4T [Fernández-Seara and Wehrli, 2000], and an \(S_{0}\) that is wrong as well. The figure below simulates this for the echo times of our data.
Fig. 20 Monoexponential fits to decay curves that are not monoexponential. Points mark the five echo times of our data, and dotted lines show the fitted monoexponential curves. (A) A voxel with a true \(S_{0}\) of 100 and a true \(T_{2}^{*}\) of 50 ms, with a linear field gradient through the slice that spans \(\Delta f\) Hz. (B) A voxel with two water compartments with different \(T_{2}^{*}\) values, such as myelin water and intra- and extra-axonal water in white matter. The fractions and relaxation times are illustrative.#
In practice, this means that the short \(T_{2}^{*}\) values in dropout regions reflect the acquisition as much as the tissue, and that \(T_{2}^{*}\) and \(S_{0}\) estimates in those regions depend strongly on which echoes are used in the fit.
Deoxygenated blood#
Deoxyhemoglobin is paramagnetic, so blood vessels that contain it distort the magnetic field in the tissue around them. This is the source of BOLD contrast [Ogawa et al., 1990], and it contributes to \(R_{2}'\) (and, through diffusion around capillaries, to \(R_{2}\)) even at rest. For a network of randomly oriented vessels, the resulting \(R_{2}'\) is proportional to the volume fraction of the vessels, to the susceptibility difference between blood and tissue, and to the field strength [Yablonskiy and Haacke, 1994]. The susceptibility difference in turn depends on the amount of deoxyhemoglobin in the blood, so the baseline contribution of blood to \(R_{2}^{*}\) depends on the deoxygenated blood volume, the oxygen extraction fraction, and the hematocrit. Quantitative BOLD methods use exactly this relationship to map deoxygenated blood volume and oxygen extraction fraction from the shape of the signal decay [He and Yablonskiy, 2007].
Changing venous oxygenation without changing blood volume (by breathing oxygen-enriched air) changes gray matter \(R_{2}^{*}\) linearly with the deoxygenated fraction of venous blood [Croal et al., 2017]. Blood volume differs across the brain: it is higher in gray matter than in white matter, and it is very high in and around large veins, such as the sagittal sinus. Voxels that contain large veins can have very short \(T_{2}^{*}\), along with unusual signal fluctuations.
Iron#
Most of the non-heme iron in the brain is stored in ferritin, which is paramagnetic. Iron increases \(R_{2}\), but it increases \(R_{2}^{*}\) even more, because iron-rich cells and deposits create mesoscopic field inhomogeneities [Haacke et al., 2005]. In a postmortem study that measured iron chemically in the same brains that were scanned at 3T, \(R_{2}^{*}\) was linearly related to iron concentration (\(r^{2} = 0.90\)), more strongly than \(R_{2}\) was (\(r^{2} = 0.67\)) [Langkammer et al., 2010]. Iron concentration was highest in the globus pallidus, followed by the putamen, the caudate, and the thalamus, which matches the order of \(T_{2}^{*}\) values in our data.
Iron accumulates in the basal ganglia with age, and \(R_{2}^{*}\) in these nuclei increases with age as well [Aquino et al., 2009]. Iron also varies within the cortex. At high field, iron follows the myeloarchitecture of each region, varies across cortical layers, and is the dominant source of contrast between layers and between regions in \(T_{2}^{*}\)-weighted images [Fukunaga et al., 2010].
Myelin and fiber orientation#
Myelin is diamagnetic, and myelin water has a much shorter \(T_{2}\) and \(T_{2}^{*}\) than the water inside and between axons [MacKay et al., 1994]. Myelin therefore shortens \(T_{2}^{*}\) in white matter, both by adding a fast-decaying water compartment and by creating mesoscopic field inhomogeneities around the axons. In demyelinated mice, white matter \(T_{2}^{*}\) increased and the frequency contrast between gray and white matter was largely lost, which shows that myelin is a primary source of both [Lee et al., 2012]. Iron and myelin together account for much of the \(T_{1}\) and \(T_{2}^{*}\) contrast across the brain [Stüber et al., 2014].
Because myelinated axons are long cylinders, the field disturbance they create depends on the angle between the fibers and \(B_{0}\) [Wharton and Bowtell, 2012, Sati et al., 2013]. As a result, white matter \(T_{2}^{*}\) depends on the orientation of its fibers: in one study, average white matter \(T_{2}^{*}\) was 49 ms in fibers perpendicular to \(B_{0}\) and 57 ms in fibers parallel to it [Bender and Klose, 2010]. The same is true, to a lesser degree, for cortex. At 7T, cortical \(T_{2}^{*}\) is lower in heavily myelinated sensorimotor, visual, and auditory regions, and it depends on the orientation of the cortex relative to \(B_{0}\) [Cohen-Adad et al., 2012].
The compartments in white matter also mean that its decay is not truly monoexponential [Sati et al., 2013]. Panel B of Fig. 20 shows what happens when a monoexponential model is fit to such data: the fast compartment has mostly decayed by the first echo, so it is effectively missing from the fitted \(S_{0}\).
Water content and intrinsic \(T_{2}\)#
The terms above mostly affect \(R_{2}'\). \(R_{2}\) also varies across tissues, mainly with water content and with how much of that water is bound to macromolecules. The largest difference is between brain tissue and CSF. CSF is almost pure water, with a \(T_{2}\) that is much longer than that of tissue, and it has no iron, myelin, or deoxygenated blood to add \(R_{2}'\). This is why the ventricles have such long \(T_{2}^{*}\) values in Fig. 19. The last echo of our data is at 113 ms, much shorter than the \(T_{2}^{*}\) of CSF, so the decay in the ventricles is barely sampled and the \(T_{2}^{*}\) estimates there are imprecise. Voxels that contain a mix of tissue and CSF also decay with more than one rate, just like the white matter example in Fig. 20.
Field strength#
Both macroscopic and mesoscopic \(R_{2}'\) scale with the field strength [Yablonskiy and Haacke, 1994], and \(R_{2}^{*}\) increases approximately linearly with field strength in cortex, white matter, and the basal ganglia [Peters et al., 2007]. At 3T, Wansapura et al. [1999] measured gray matter \(T_{2}^{*}\) values of 41.6 ms in occipital cortex and 51.8 ms in frontal cortex, and at 7T, Cohen-Adad et al. [2012] measured an average cortical \(T_{2}^{*}\) of 32 ms. Absolute \(T_{2}^{*}\) values, and the contrast between regions, are therefore specific to the field strength, as well as to the other acquisition parameters described above.
Does baseline neural activity affect \(T_{2}^{*}\)?#
Yes, but only slightly. Neural activity affects \(T_{2}^{*}\) through blood oxygenation and blood volume, so regions with different baseline activity could in principle have different baseline \(T_{2}^{*}\) values. In practice, the brain at rest matches blood flow to its metabolic demands, so the fraction of oxygen extracted from the blood is remarkably uniform across the brain at rest [Raichle et al., 2001]. Regional differences in baseline metabolism therefore produce much smaller differences in deoxyhemoglobin than one might expect from the differences in metabolism alone.
We can also compare the size of the effects directly. A BOLD signal change of \(\Delta S / S\) at echo time \(TE\) corresponds to a change in \(R_{2}^{*}\) of roughly \(\Delta R_{2}^{*} \approx -(\Delta S / S) / TE\). A large, 1% BOLD response at TE = 30 ms therefore corresponds to a change of about 0.33 \(s^{-1}\). In comparison, the difference in mean \(R_{2}^{*}\) between typical cortex and lateral orbitofrontal cortex in our data is about 12 \(s^{-1}\). Changes in baseline activity, and in physiological factors that affect the whole brain, such as arterial \(CO_{2}\), hematocrit, or caffeine, can shift \(T_{2}^{*}\) a little, but the spatial pattern of mean \(T_{2}^{*}\) is dominated by the static mechanisms described above.
Sources of \(S_{0}\) variability#
\(S_{0}\) is often described as the “proton density”, but it is really just the intercept of the decay model: the signal we would measure if we could acquire an echo at TE = 0. For a gradient-echo sequence in a steady state, this is approximately
where \(C(\mathbf{r})\) is the sensitivity of the receive coil at location \(\mathbf{r}\), \(\rho\) is the proton density, \(\alpha\) is the flip angle that the voxel actually experiences, and the fraction describes how much the longitudinal magnetization has recovered between excitations. Several of these terms vary across the brain.
Proton density#
The density of MR-visible water protons is higher in CSF than in gray matter, and higher in gray matter than in white matter. Quantitative water content mapping requires correcting for every other term in (7) [Neeb et al., 2006], so \(S_{0}\) from a multi-echo fMRI scan is at best a heavily weighted version of proton density.
\(T_{1}\) saturation#
fMRI uses short repetition times, which leave little time for the longitudinal magnetization to recover. Tissues with a long \(T_{1}\) recover less between excitations, so they have a lower \(S_{0}\). At 3T, \(T_{1}\) is about 1.3 s in gray matter and 0.8 s in white matter [Wansapura et al., 1999], while the \(T_{1}\) of ventricular CSF is about 4.3 s at any field strength [Rooney et al., 2007]. The figure below shows the recovery term of (7) for these tissues. At the TR of our data, CSF is saturated much more than tissue, which offsets much or all of its higher proton density, depending on the flip angle. This is the main reason why the ventricles are darker than the surrounding tissue in the \(S_{0}\) map, even though CSF contains more water. The same effect makes \(S_{0}\) sensitive to anything that changes the longitudinal magnetization, such as the inflow of fresh blood, head motion (through spin history effects), and the flip angle that each voxel actually experiences, which is not uniform across the head at 3T and above.
Fig. 21 The steady-state signal of a spoiled gradient-echo sequence, as a fraction of the equilibrium magnetization (\(M_{0}\), the signal of a 90° pulse after full recovery), for the \(T_{1}\) values of gray matter and white matter at 3T and of CSF. The dotted line marks the TR of the data in this book.#
Coil sensitivity#
Modern head coils are arrays of many small receive coils placed around the head. Each element is most sensitive to the tissue right next to it, and combining them gives the sensitivity of a small surface coil over the whole field of view [Roemer et al., 1990]. The gain in sensitivity is much larger near the surface of the brain than at its center. For example, a 32-channel array improved SNR by up to 3.5 times in cortex, but only by 1.4 times in the corpus callosum, compared with an 8-channel array [Wiggins et al., 2006]. The transmit field is not uniform either. At 3T and above, the wavelength of the radiofrequency field in tissue is similar to the size of the head, so the flip angle that each voxel actually experiences (\(\alpha\) in (7)) varies across the brain, and is typically higher in the center of the head than at its edges. Many scanners also apply an intensity normalization that partially removes the receive coil’s profile. The net pattern depends on the coil, the scanner, and the reconstruction, but receive sensitivity, transmit field, and normalization all multiply the signal at every echo by the same amount, so they appear entirely in \(S_{0}\) and not at all in \(T_{2}^{*}\). This is why \(S_{0}\) maps contain large, smooth variations that have nothing to do with the tissue, and why their absolute values are not comparable across coils or scanners.
Inflow#
At short repetition times, blood that flows into the imaging slab has not experienced the previous excitations, so it has more longitudinal magnetization than the stationary tissue around it. This raises the signal near large arteries and veins, particularly at the edges of the slab and with short TRs and large flip angles [Gao and Liu, 2012]. Inflow mostly increases the longitudinal magnetization before any transverse decay happens, so it appears mainly in \(S_{0}\). However, the inflowing blood also has its own \(T_{2}^{*}\), so a change in how much fresh blood a voxel contains changes the mix of compartments in the voxel, and can bias the fitted \(T_{2}^{*}\) as well.
Model misspecification#
Finally, \(S_{0}\) is an extrapolation, so it inherits every error in the decay model. When the decay is not monoexponential, as in Fig. 20, the intercept of the fitted line is not the true signal at TE = 0. Fast-decaying compartments, such as myelin water, are mostly missing from \(S_{0}\), and through-slice field gradients can make \(S_{0}\) either too high or too low. These errors are largest in exactly the regions where \(T_{2}^{*}\) is hardest to estimate.
What about changes over time?#
This chapter has focused on the mean values of \(T_{2}^{*}\) and \(S_{0}\), but the same mechanisms help explain why they fluctuate. Fluctuations in \(S_{0}\) are often treated as noise, since head motion, inflow, and changes in coil sensitivity as the head moves all appear in \(S_{0}\). However, not every \(S_{0}\) fluctuation is an artifact. Blood and tissue have different \(S_{0}\) values (through their different \(T_{1}\) values, proton densities, and inflow), so a change in blood volume changes the composition of a voxel and, with it, the fitted \(S_{0}\). Vascular space occupancy (VASO) fMRI is based on the same principle, since it measures changes in blood volume through the \(T_{1}\) difference between blood and tissue [Lu et al., 2003]. Multi-echo studies have attributed negative BOLD signals near large veins to increases in local blood volume [Bianciardi et al., 2011], and have found that the TE = 0 intercept of the BOLD response in visual cortex has its own time course, which was best explained by a combination of deoxyhemoglobin and venous blood volume changes [Havlicek et al., 2017]. Deconvolution methods that estimate \(T_{2}^{*}\) and \(S_{0}\) fluctuations separately, such as multi-echo sparse paradigm free mapping [Caballero-Gaudes et al., 2019], can be used to study these effects.
Practical implications#
\(T_{2}^{*}\) maps are not tissue maps. Mean \(T_{2}^{*}\) mixes properties of the tissue (iron, myelin, blood, water) with properties of the acquisition (field strength, voxel size, slice orientation, head position, and shimming). Values are not directly comparable across scanners or protocols.
\(S_{0}\) maps are mostly not interpretable. They are dominated by coil sensitivity and \(T_{1}\) saturation, and they absorb errors in the decay model. They are still useful for quality control, for example to spot coil problems or inflow artifacts.
Regional \(T_{2}^{*}\) variability is why optimal combination helps. Because \(T_{2}^{*}\) varies so much across the brain, no single echo time is optimal everywhere. Optimal combination weights each echo by its expected BOLD sensitivity in each voxel, using the voxel’s own \(T_{2}^{*}\).
Estimates are least reliable where they matter most. In dropout regions, only the first few echoes have usable signal, and the decay is not monoexponential, so \(T_{2}^{*}\) and \(S_{0}\) estimates depend strongly on which echoes are included in the fit.
tedana’s adaptive mask exists to handle this.Mean values do not classify components. Denoising methods like
tedanarely on how signal changes depend on echo time, not on the mean \(T_{2}^{*}\) or \(S_{0}\) of a voxel. The next chapter describes how these fluctuations are used.